Invitation to bid – RFP for Transit Ambulance
PRATT COUNTY EMS
Seeking bids for 2024 FORD “Transit” preferably with 3.5L ECO BOOST
AMBULANCE BID SPECIFICATION
All bids will remain sealed until opened in the Pratt County Clerk’s Office at 9 am on December 1
st
. Bids may be mailed to the Pratt County Clerk’s Office Attn: EMS BID at 300 S. Ninnescah, Pratt KS 67124 and must be received in the Clerk’s Office prior to 9 am on the date of the bid opening. Bids may also be submitted electronically to the County Clerk at
lvoss@prattcounty.org
For security reasons, you must enable JavaScript to view this E-mail address.
. Electronic Bids must also be received prior to 9 am on December 1
st
. Pratt County takes no responsibility for bids not received prior to the bid opening date.
Bid:_________________________________________
Date until which bid is good:____________________________
Signature:_____________________________________
Printed Name:_________________________________
Company Name:_______________________________
Company Address:_____________________________
Company Phone:_______________________________
For any area below which you wish to bid an equivalent alternative please indicate the exact specifications of your suggested alternative part/specification.
INDEX
SECTION #
SECTION TITLE
--1--
3.5 11O VOLT AC SYSTEM
3.4 12 VOLT DC SYSTEM
--A--
1.13 ALTERNATORS
9.2 AMD MEMBERSHIP
2.4 ANTENNA GROUND PLANE
7.3 ANTENNA PRE-WIRE
1.3 AMBULANCE INTERFACE MODULE
1.9 AXLE, REAR
--B--
4.17 BACK BOARD STORAGE
1.12 BATTERIES
1.7 BRAKES
4.4 BULKHEAD CABINETS
5.1 BUMPER, REAR STEP
--C--
4.2 CABINETS, PATIENT COMPARTMENT
4.3 CABINETS, LEFT WALL
1.0 CHASSIS
1.21 CHASSIS, MISCELLANEOUS ITEMS
1.20 CHASSIS, TRIM PACKAGE
1.1 CHASSIS & WHEELBASE
4.13 CLIMATE CONTROL
2.0 CONVERSION CONSTRUCTION
4.14 COT MOUNT
1.18 COOLING SYSTEM, ENGINE
--D--
5.2 DECALS, “STAR-OF-LIFE”
7.1 DECALS, “NO SMOKING” & “FASTEN SEAT BELT”
-E--
3.1 ELECTRICAL SERVICE PANEL
3.2 ELECTRICAL SERVICE PANEL ACCESS
3.0 ELECTRICAL SYSTEM
3.3 ELECTRICAL WIRING
1.2 ENGINE
1.18 ENGINE COOLING SYSTEM
5.0 EXTERIOR
--F--
7.4 FABRICS, BLOOD BORNE PATHOGENS
4.1 FLOOR, PATIENT COMPARTMENT
9.4 FORD POOL PROGRAM
9.3 FORD QVM PROGRAM
1.10 FUEL TANK
--G--
1.4 GAUGES AND METERS
4.11 GRAB RAIL, OVERHEAD
--H--
4.9 HEADLINER
1.17 HEATER AND AIR CONDITIONER, CHASSIS
--I--
4.12 INSULATION
4.10 INTERIOR PANELING
7.2 I.V. BAG HANGERS
-K-
-
KKK-A-1822-F CERTIFICATION
--L--
3.6 LIGHTING, EMERGENCY
3.10 LIGHTING, PATIENT COMPARTMENT DOME
3.13.1 LOW VOLTAGE ALARM
--M--
7.5 MANUALS
1.19 MIRRORS, OUTSIDE REAR-VIEW
7.0 MISCELLANEOUS EQUIPMENT
--O--
4.16 OXYGEN COMPARTMENT
4.15 OXYGEN OUTLETS
--P--
5.1 PAINT
4.0 PATIENT COMPARTMENT
6.0 PAYLOAD
6.1 PAYLOAD
--R--
9.5 REMOUNTING AND REFURBISHING
2.1 ROOF RAISED
2.2 ROLL-OVER PROTECTION
9.0 REQUIREMENTS OF THE MANUFACTURER
--S--
3.7 SCENE LIGHTS
7.6 SCHEMATICS, WIRING
2.1 SEAT BELT ANCHOR SYSTEM
1.16 SEATS, DRIVERS COMPARTMENT
4.6 SEAT, EMT/ATTENDANT
4.7 SHARP'S & WASTE CONTAINERS
3.8 SIREN AND SPEAKERS
3.9 SPOTLIGHT
1.5 SPRINGS AND AXLES
4.5 SQUAD BENCH
1.6 STEERING
3.11 SUCTION - ON BOARD
3.13 SWITCH CONSOLE, DRIVER’S
3.14 SWITCH CONSOLE, PATIENT COMPARTMENT
--T--
1.8 TRANSMISSION
--U--
4.8 UPHOLSTERY
--V--
3.12 VENTILATION
--W--
8.0 WARRANTY
8.1 WARRANTY COVERAGE
1.11 WHEELS AND TIRES
1.14 WINDOWS
1.15 WINDSHIELD WIPERS
2024 MID-ROOF TYPE II
AMBULANCE SPECIFICATION
Note: Ambulance shall be delivered to Pratt County EMS in the 2024 calendar year
.
COMPLY?………………………………YES_____ NO_____
1.0 CHASSIS
1.1 CHASSIS AND WHEELBASE
2024 Ford Transit van with single rear wheels; mid roof, 148-inch wheelbase, 9500 lb. GVWR; front stabilizer bar; Ford Ambulance Prep Package 47A.
COMPLY?………………………………YES_____ NO_____
1.2 ENGINE
Ford 3.5L V-6 Eco Boost Gas Engine.
COMPLY?………………………………YES_____ NO_____
1.3 AMBULANCE INTERFACE MODULE
An “Intermotive” Ambulance Interface Module shall be standard. The Interface Module is to provide fast idle system controls in order to increase electrical output of the vehicle. When the vehicle is in park, service brake disengaged, the parking brake is set, and the water Temperature is at 230
o
F the Interface Module shall electronically adjust the engine idle (up or down) to maintain proper electrical system voltage.
COMPLY?………………………………YES_____ NO_____
1.4 GAUGES AND METERS
Speedometer, odometer, tachometer, fuel gauge, temperature.
COMPLY?………………………………YES_____ NO_____
1.5 SPRINGS AND AXLES
Front axle; Independent MacPherson Strut with stabilized bar, 4130 pounds GAWR. Rear Solid axle, leaf springs and heavy-duty shocks, 5,512 pounds GAWR.
COMPLY?………………………………YES_____ NO_____
1.6 STEERING
Hydraulic power rack and pinion
COMPLY?………………………………YES_____ NO_____
1.7 BRAKES
Four Wheel disc with four-wheel anti-lock.
COMPLY?………………………………YES_____ NO_____
1.8 TRANSMISSION
Six speed automatic overdrive with Select Shift
COMPLY?………………………………YES_____ NO_____
1.9 AXLE, REAR
3.73 gear ratio. Limited slip differential.
COMPLY?………………………………YES_____ NO_____
1.10 FUEL TANK
Single 25-gallon capacity fuel tank.
COMPLY?………………………………YES_____ NO_____
1.11 WHEELS AND TIRES
Five (5) LT 235/65R16 BSW All-season radial tires mounted on steel wheels with OEM hub caps. Four on unit with one spare between rear frame rails and below vehicle floor.
COMPLY?………………………………YES_____ NO_____
1.12 BATTERIES
Two Heavy Duty Batteries shall be mounted under the driver’s seat, wired paralleled in the OEM configuration that complies with Ford QVM and KKK-1822-F requirements. Batteries will be wired so that both will always be used for starting. The power cut off switch circuit shall be protected by a 250 amp fuse. The Ford ignition key activates the cut off switch. Power can be provided to the conversion without the engine running by turning the ignition key to accessory position.
COMPLY?………………………………YES_____ NO_____
1.13 ALTERNATORS
Ford OEM Dual 250-amp heavy duty alternators.
COMPLY?………………………………YES_____ NO_____
1.14 WINDOWS
Tinted safety glass is installed in all exterior windows.
COMPLY?………………………………YES_____ NO_____
1.15 WINDSHIELD WIPERS
Two speed electric, rain sensing, with washer and intermittent control
COMPLY?………………………………YES_____ NO_____
1.16 SEATS, DRIVER'S COMPARTMENT
Deluxe cloth OEM High Back Captains chairs, with fold-down armrests and seat belts and shoulder harnesses. A (3) three glove holder shall be installed in the chassis cab at the ceiling level behind the drivers seat.
COMPLY?………………………………YES_____ NO_____
1.17 HEATER AND AIR CONDITIONER, CHASSIS
OEM heavy duty, high output.
COMPLY?………………………………YES_____ NO_____
1.18 ENGINE COOLING SYSTEM
Heavy-duty liquid system using a 50-50 mix of permanent type anti-freeze and water for protection to -40 degrees Fahrenheit.
COMPLY?………………………………YES_____ NO_____
1.19 MIRRORS, OUTSIDE REAR-VIEW
OEM dual black mirrors with integrated convex mirrors below the mirror glass; all mirrors are below eye level. They shall be power adjustable and fold-away.
COMPLY?………………………………YES_____ NO_____
1.20 CHASSIS TRIM PACKAGE
Exterior upgrade package; Full 16” sport wheel covers, chrome grill, aero style daytime running headlights. Interior options; Color keyed door trim with map pockets, full rubber floor mat, padded sunvisors, courtesy and dual dome lights, AM/FM/ Stereo Radio with clock, MP3 input and dual cab speakers. Power door locks w/ remote keyless entry, power windows, cruise control, tilt steering wheel, and rear view camera with screen located in the rear view mirror. Rear door trim shall be included. An additional door handle shall be installed to the side entry door to allow for easier opening from the interior.
Install an A-C pillar running board on the passenger side and A-B running board on the drivers side.
COMPLY?………………………………YES_____ NO_____
1.21 CHASSIS, MISCELLANEOUS ITEMS
Dual pitch horn, reduced sound level exhaust, OEM standard undercoating, stepwell pad and dual air bags.
COMPLY?………………………………YES_____ NO_____
2.0 CONVERSION CONSTRUCTION
2.1 SEAT BELT ANCHOR SYSTEM
There is to be a full beam welded to the interior sidewall behind the squad bench. This beam is installed to provide a superior structure anchor point for the installation of the restraint system in the patient compartment.
COMPLY?………………………………YES_____ NO_____
3.0 ELECTRICAL SYSTEM
3.1 ELECTRICAL SERVICE PANEL
All circuits shall be rated to carry at least 125% of its maximum load. Manual reset circuit breakers and relays shall protect each circuit. Each circuit that is rated more than three (3) amps shall be switched by use of a relay.
The electrical system shall be a multi-plex V-Mux system with control panels in the action area and cab.
COMPLY?………………………………YES_____ NO_____
3.2 ELECTRICAL SERVICE PANEL ACCESS
There shall also be a hinged access panel located above pass through window which will house the main wiring system for the entire unit, such as circuit breakers, and relays, along with numerical listings of each circuit.
COMPLY?………………………………YES_____ NO_____
3.3 ELECTRICAL WIRING
All the vehicle's electrical equipment shall be served by circuits separate and distinct from the chassis electrical system. All electrical wiring shall be run in grease, oil, heat and moisture resistant looming. Harnesses shall be fastened with vinyl-clad clamps and grommeted at any area they contact a metal edge.
Every load carrying wire shall be minimum of 12 or 14 gauge and shall be color coded and heat-embossed with its function every 4 to 6 inches.
There shall be at least a six-inch service loop of wire at the point of attachment to each component. All electrical connections shall be crimped; the use of Scotch-locks is strictly prohibited.
A Vanner Model LSC12-1100 Inverter shall be included.
COMPLY?………………………………YES_____ NO_____
3.4 12 VOLT DC SYSTEM
There shall be two (2) Cigar style 12VDC outlets. Both located in the action area.
COMPLY?………………………………YES_____ NO_____
3.5 11O VOLT AC SYSTEM
There shall be a weatherproof 11OV-125V male receptacle rated at 20 amps with a spring-loaded cover assembly located on the driver's side close to the driver's door for incoming 110 volt power. This receptacle shall be labeled. It shall be wired through one 20-amp circuit breaker. An indicator light shall be installed above the outlet. The circuit shall include two (6) 110-volt interior receptacles, one (1) located in the action area and one (2) located over the squad bench, (3) in the front wall. All outlets shall illuminate per KKK-A-1822-F.
COMPLY?………………………………YES_____ NO_____
3.6 LIGHTING, EMERGENCY
The unit shall be equipped with one Whelen Light POD with 700 series lights; 2) Red LED, 2) Clear LED, 2) Blue LED and the following warning lights:
16 Whelen 700 Series LED emergency & flood lights as follows:
6) Facing forward in a Whelen light pod.
6) 700 Facing rearward
4) 700 Facing right
4) 700 Facing left
2) Whelen Series ION-T Split LED lights mounted on each front fender as
intersection warning lights.
2) Whelen Series ION-T Split LED lights mounted over each rear wheel as
intersection warning lights.
2) Whelen Series ION-T Split LED lights mounted on the grill as forward-facing warning lights.
LIGHTING, EMERGENCY
, (continued)
Circuit shall have a dual mode switch. "Primary" shall flash all lights, "Secondary" shall
flash top red lights and amber.
COMPLY?………………………………YES_____ NO_____
3.7 SCENE LIGHTS
Scene lights shall be four (4) Whelen Series 7SCOENZR LED surface mounted two (2) lights on the left side and two (2) lights on the right side. A separate switch on the driver’s switch panel shall control each pair. In addition, the right side and rear scene lights shall activate when the right side or rear doors, respectfully, are open.
COMPLY?………………………………YES_____ NO_____
3.8 SIREN AND SPEAKERS
Siren shall be a Whelen 295HFSC9 Dual Tone with Wail, Yelp, Hi/Lo and Phaser sounds.
Cast SA 3800 series siren speakers w/ black finish shall be installed in the front bumper.
COMPLY?………………………………YES_____ NO_____
3.9 SPOTLIGHT
There shall be a "300,000 candle power" spotlight, with eight foot coiled cord and momentary switch, permanently wired into front console. A “Mic” style storage clip shall be provided.
COMPLY?………………………………YES_____ NO_____
3.10 LIGHTING, PATIENT COMPARTMENT DOME
The ceiling headliner shall contain eight (8) Intertek LED High - Low intensity dome lights. The left and right banks of lights shall be switched separately. The left bank high mode will be activated by opening of the rear doors; right bank activated by opening of the side door. In addition, a 6” LED light shall be installed in the action area.
COMPLY?………………………………YES_____ NO_____
3.11 SUCTION - ON BOARD
An SSCOR suction system shall be provided with the canister mounted on the back wall above the action area countertop.
COMPLY?………………………………YES_____ NO_____
3.12 VENTILATION
A 138-CFM exhaust fan shall be mounted near the ceiling and shall be activated by a switch on the action wall.
COMPLY?………………………………YES_____ NO_____
3.13 SWITCH CONSOLE, DRIVER'S
There shall be a console mounted between the two front seats. There shall be space provided for the installation of siren below the switches. OEM cup holders will be accessible. The switch panel shall be molded, aesthetically appealing, and incorporate modern switches and gauges as follows:
Module Master Switch
Emergency Master Switch
Primary/Secondary
Siren/Horn
Left Scene
Right Scene
Rear Scene
Back up Alarm Disable
Silent Intercom Lights
Door Ajar Light
Voltmeter, Digital
COMPLY?………………………………YES_____ NO_____
3.13.1 LOW VOLTAGE ALARM
A Low Voltage Alarm shall sound when voltage drops below 11.8 volts for more than 120 seconds.
COMPLY? ……………………………... YES_____ NO _____
3.14 SWITCH CONSOLE, PATIENT COMPARTMENT
The following switches shall be in the rear control panel:
Module Master Switch
Left Dome High / Low
Right Dome High / Low
Silent Intercom Switches
Buzzer
Exhaust Fan
Electric Suction
3-Speed Blower Control for Heat/ AC
Thermostatically controlled Heat/AC
COMPLY?………………………………YES_____ NO_____
All switches in front and rear panels shall be positive contact rocker type switches that are permanently marked by function, illuminate when activated and backlit for night visibility. All switches are to be independently replaceable.
4.0 PATIENT COMPARTMENT
4.1 FLOOR, PATIENT COMPARTMENT
The subfloor there shall be ¾” exterior grade plywood that is caulked and sealed. The floor is then covered with a single piece of Lon Coin flooring, which shall roll up the left wall approximately 3". Coving shall be installed at the base of the left wall running the full length of the floor prior to the installation of the linoleum. Flooring shall be sealed at all edges to prevent liquids from seeping between the floor and cabinets.
COMPLY?………………………………YES_____ NO_____
A formed 1 ¾”, full width stainless steel floor protection strip shall be installed forward of the rear patient compartment door seal.
COMPLY? ……………………………………… YES _____ NO _____
4.2 CABINETS, PATIENT COMPARTMENT
All interior cabinets shall be built using ¾” cabinet grade, solid core plywood. The use of plywood of any lesser quality or thickness is strictly prohibited.
COMPLY? ……………………………………… YES _____ NO _____
All interior cabinets shall be constructed using wood screws. The use of nails in the fastening of cabinet components is strictly prohibited.
COMPLY?………………………………YES_____ NO_____
Exposed cabinet surfaces, interior and exterior, are to be covered with “Wilsonart” laminate. Sliding Plexiglas windows shall be 1/4" thick with full height extruded aluminum handles mounted in full perimeter slide track. Door catches shall be flush-mount slam-type positive latching.
COMPLY? ……………………………………… YES _____ NO _____
4.3 CABINETS, LEFT WALL
The left wall shall incorporate a floor-mounted climate control unit. Unit shall be drained directly through the floor. Air intake shall be at floor level while output shall be ducted overhead. Left rear storage shall be provided for stair chair. Forward of that shall be two large cabinets with sliding glass doors and adjustable shelves. Running from the front to back, at the ceiling line shall be three cabinets with flip-up plexi glass doors. At the front of the left wall shall be the V-MUX switch panel, oxygen outlets, 12V outlets and digital thermostat. Next to the switch panel and above it will be two small cabinets with sliding plexi glass doors. A 12” Gab handle shall be installed for mounting of an IV pump. Above the action area a (3) three glove storage shall be installed. A digital clock shall be installed on the cabinet wall.
COMPLY?………………………………YES_____ NO_____
4.4 BULKHEAD & CABINETS
The front wall shall incorporate a 12” wide cabinet with (2) adjustable shelves and plexi doors. (2) two 110V outlet shall be installed (1) one at the top of the cab and (1) one at the bottom Below shall be an 8” tall by 28” dual cabinet split in the middle with tip down doors. One side shall have a Simplex lock. Below shall be a Dometic refrigerator drawer with Simplex lock. Main O2 shall be mounted under the cabinet stack in a transverse housing with (2) “M” brackets tied together. On the door side of the cabinet a 12” grab handle shall be installed. The attendant seat shall be incorporate a 3-point child seat. To the rear of the seat shall be (1) one O2 outlet and (1) one 110V/USB outlet. A fitted aluminum barrier shall be installed between the cab & module to prevent the chance of infectious airborne particles from reaching the drivers compartment.
COMPLY?………………………………YES_____ NO_____
4.5 SQUAD BENCH
The squad bench shall be constructed of 3/4" cabinet grade, solid core, 7-ply Birch Plywood. Storage space shall be provided under the hinged squad bench seat with access via a paddle latch. There shall be 2-point seat belts for 3 seating locations with all belts being tested and certified to meet or exceed FMVSS 206. Additionally, there are to be 2 belts provided for the securing of a second patient on the Squad Bench. A drop in sharps shall be included at the front of the bench and a drop in waste area shall be at the rear of the bench. (2) two 110V outlets shall be installed on the bench wall along with a dial timer. A cargo net shall be installed at the head of the bench. There shall be a slot at the rear of the bench that allows spine board storage.
COMPLY?………………………………YES_____ NO_____
4.6 SEAT, EMT / ATTENDANT
An attendant seat with an integrated child seat shall be located at the head of the primary cot. It shall be a molded/contoured seamless seat with integrated 3-point belt system that has been tested and certified to meet or exceed FMVSS 206 and mounted on the transfer O2 compartment.
COMPLY?………………………………YES_____ NO_____
4.7 SHARP'S & WASTE CONTAINERS
There shall be a Sharp's Container mounted at the head of the Squad Bench with access to each via Plex-glass “Flip-up Doors” clearly labeled as “Sharps”. Removal shall be via a forward-facing access door at the head of the bench. The “Waste” Container shall be located at the rear of the bench.
COMPLY?………………………………YES_____ NO_____
4.8 UPHOLSTERY
All seat cushions and protective pads shall be constructed of either l/4”, 1”, 2-1/2", and 3” fire-retardant foam covered with minimum 40 ounce vinyl. All seat cushions shall be vacuum-formed seamless.
COMPLY?………………………………YES_____ NO_____
4.9 HEADLINER
The headliner shall be constructed of a thermoplastic core sandwiched between two sheets of aluminum finished in semi-gloss white. The headliner is to provide for the limitation of heat transfer from the roof, reflection of light and be easily cleaned. There is to be a removable center section to gain access to wiring that is covered with a padded vinyl. (1) IV hook shall be installed in the headliner.
COMPLY?………………………………YES_____ NO_____
4.10 INTERIOR PANELING
Walls shall be covered with high pressure Wilsonart laminate material. Exposed surface shall be mar, dent and scratch resistant.
COMPLY?………………………………YES_____ NO_____
4.11 GRAB RAIL, OVERHEAD
A full-length 7/8" polished grab rail shall be installed on patient compartment ceiling. This rail shall be capable of supporting a minimum of 300 pounds.
COMPLY?………………………………YES_____ NO_____
4.12 INSULATION
The entire patient compartment shall be blanketed with a layer of R-14.5 “Reflectix” insulation to provide exceptional insulation and sound deadening qualities. Additionally, fiberglass insulation shall be added to numerous areas of the ceiling and side walls.
COMPLY?………………………………YES_____ NO_____
4.13 CLIMATE CONTROL
Rear climate control shall he mounted at floor level at left front of patient compartment to shorten refrigerant and anti-freeze hoses. Condensation from high humid conditions shall drain directly through floor to avoid water build up and "spitting' on humid days. Air intake shall be at floor level, while output shall be at four vents located in the ceiling for increased airflow.
The unit shall be a Danhard with 27,000 BTU cooling capacity and a 28,000 BTU heating capacity. The blower motor shall have permanent magnets and be capable of delivering 630 CFM of airflow. The blower must be removable without removing entire heat/cool unit and without disconnection of any coolant lines.
Both heating and cooling shall be controlled by a thermostat with 3-speed manual fan speed control. The digital thermostat shall be located on the action wall.
COMPLY?………………………………YES_____ NO_____
4.14 COT MOUNT
A Stryker Universal Floor Plate shall be installed for the installation of a Cot Mount.
COMPLY?………………………………YES_____ NO_____
4.15 OXYGEN OUTLETS
Oxygen system shall be plumbed with conductive hose from oxygen compartment to two AMVEX, Ohio style oxygen outlets, (1) located in the action wall area and (1) one at the front wall.
COMPLY?………………………………YES_____ NO_____
4.16 OXYGEN COMPARTMENT
Shall be located transverse in the bulkhead at floor level with curbside access at the patient compartment side entry door and securely fastened to the floor. (2) two Zico “QRMV” Slide-Out O-2 Bottle Brackets shall be installed to secure the tanks. These mounts shall fit "M" size cylinders. This oxygen bottles shall be accessible through a one-piece door with a positive latch and shall be removable from outside the unit while standing, without physically entering the patient compartment. A plexi glass access door is to be provided for access to the O2 bottles on/off valve and gauge with a second plexi glass access door at the foot of the bottle.
COMPLY?………………………………YES_____ NO_____
4.17 BACK BOARD STORAGE
There shall be horizontal storage provided on the “face” of the Squad Bench for the storage of two (2) Backboards with access via the rear patient compartment entry door.
COMPLY?………………………………YES_____ NO_____
5.0 EXTERIOR
5.1 PAINT
The chassis shall have the Ford factory blue paint by Ford.
COMPLY?………………………………YES_____ NO_____
5.2 DECALS, GRAPHICS
The ambulance graphics shall be reflective and match the departments current design.
COMPLY?………………………………YES_____ NO_____
6.0 PAYLOAD
6.1 PAYLOAD
Payload of standard unit to be 2200 lbs. (GVWR minus curb weight). The weight of any options shall be considered parts of the payload.
COMPLY………………………………YES_____ NO_____
7.0 MISCELLANEOUS EQUIPMENT
7.1 DECALS, NO SMOKING & FASTEN SEAT BELT
There shall be two (2) "NO SMOKING / FASTEN SEAT BELTS " signs, one each in the driver's compartment, and in the patient's compartment
COMPLY………………………………YES_____ NO_____
There shall be two Perko “clip” style I.V. Bag Hangers with 8” Velcro retaining straps, one mounted above the squad bench, and one mounted on the left wall.
COMPLY………………………………YES_____ NO_____
Two pre-wires for antenna coaxial cables delivered to the rear of passenger seat
COMPLY………………………………YES_____ NO_____
-
FABRICS, BLOOD BORNE PATHOGENS
There shall be no material used in the patient compartment that could absorb blood borne pathogens.
COMPLY………………………………YES_____ NO_____
7.5 MANUALS
There shall be one complete owner's manual for the entire unit. It is loaded on a flash drive
COMPLY………………………………YES_____ NO_____
7.6 SCHEMATICS, WIRING
There shall be a complete specific wiring schematic.
COMPLY………………………………YES_____ NO_____
8.0 WARRANTY
8.1 WARRANTY COVERAGE
Three year / 36,000-mile product conversion warranty
Six year / 72,000-mile electrical system warranty
COMPLY?………………………………YES_____ NO_____
9.0 REQUIREMENTS OF THE MANUFACTURER
9.1 KKK-A-1822-F CERTIFICATION
This unit shall meet all KKK-A-1822-F specifications, and all subsequent revisions, and the manufacturer shall have current documentation of compliance with all
KKK-A-1882-F standards.
COMPLY………………………………YES_____ NO_____
9.2 AMD MEMBERSHIP
The manufacturer shall be a current member in good standing of the Ambulance Manufacturers Division (AMD) of the National Truck & Equipment Association (NTEA).
The unit shall be built in compliance with all AMD “Standards”.
COMPLY………………………………YES_____ NO_____
9.3 FORD QVM PROGRAM
This unit shall meet all Ford QVM Program requirements and the manufacturer shall be a
current member in good standing of the Ford QVM Program.
COMPLY? ………………………………YES _____ NO _____
9.4 FORD POOL ACCOUNT PROGRAM
The manufacturer shall be a current member in good standing of the Ford Pool Account Program.
COMPLY? ………………………………...YES _____ NO _____